As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v4 7.4
- ATTENTION: Exploitable remotely
- Vendor: Siemens
- Equipment: Mendix Applications
- Vulnerability: Improper Privilege Management
2. RISK EVALUATION
Successful exploitation requires to guess the identification of a target role which contains the elevated access rights.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Siemens products, are affected:
- Siemens Mendix Applications using Mendix 9: Versions prior to V9.24.22 and after V9.3.0
- Siemens Mendix Applications using Mendix 10: Versions prior to V10.11.0
- Siemens Mendix Applications using Mendix 10 (V10.6): Versions prior V10.6.9
3.2 Vulnerability Overview
3.2.1 IMPROPER PRIVILEGE MANAGEMENT CWE-269
Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights.
CVE-2024-33500 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2024-33500. A base score of 7.4 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Defense Industrial Base, Energy, Financial Services, Government Facilities, Healthcare and Public Health, Transportation Systems
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Achmea Security Assessment Team reported this vulnerability to Siemens.
4. MITIGATIONS
Siemens recommends users update the product to following versions:
- Mendix Applications using Mendix 9: Update to V9.24.22 or later version
- Mendix Applications using Mendix 10: Update to V10.11.0 or later version
-
Mendix Applications using Mendix 10 (V10.6): Update to V10.6.9 or later version
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-540640 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
5. UPDATE HISTORY
- June 13, 2024: Initial Publication
Motorola Solutions Vigilant License Plate Readers
1. EXECUTIVE SUMMARY
- CVSS v4 8.7
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Motorola Solutions
- Equipment: Vigilant Fixed LPR Coms Box (BCAV1F2-C600)
- Vulnerabilities: Authentication Bypass Using an Alternate Path or Channel, Cleartext Storage in a File or on Disk, Use of Hard-coded Credentials, Insufficiently Protected Credentials, Missing Encryption of Sensitive Data, Authentication Bypass by Capture-replay
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to tamper with the device, access sensitive information and credentials, or perform a replay attack.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following versions of Motorola Vigilant License Plate Readers are affected:
- Vigilant Fixed LPR Coms Box (BCAV1F2-C600): Versions 3.1.171.9 and prior
3.2 Vulnerability Overview
3.2.1 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288
The affected product is vulnerable to an attacker modifying the bootloader by using custom arguments to bypass authentication and gain access to the file system and obtain password hashes.
CVE-2024-38279 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2024-38279. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.2.2 CLEARTEXT STORAGE IN A FILE OR ON DISK CWE-313
An unauthorized user is able to gain access to sensitive data, including credentials, by physically retrieving the hard disk of the product as the data is stored in clear text.
CVE-2024-38280 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38280. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.3 USE OF HARD-CODED CREDENTIALS CWE-798
An attacker can access the maintenance console using hard coded credentials for a hidden wireless network on the device.
CVE-2024-38281 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.0 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38281. A base score of 8.6 has been calculated; the CVSS vector string is (CVSS4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.4 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522
Utilizing default credentials, an attacker is able to log into the camera’s operating system which could allow changes to be made to the operations or shutdown the camera requiring a physical reboot of the system.
CVE-2024-38282 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38282. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.5 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311
Sensitive customer information is stored in the device without encryption.
CVE-2024-38283 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.6 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A CVSS v4 score has also been calculated for CVE-2024-38283. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).
3.2.6 AUTHENTICATION BYPASS BY CAPTURE-REPLAY CWE-294
Transmitted data is logged between the device and the backend service. An attacker could use these logs to perform a replay attack to replicate calls.
CVE-2024-38284 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38284. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.2.7 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522
Logs storing credentials are insufficiently protected and can be decoded through the use of open source tools.
CVE-2024-38285 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2024-38285. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Emergency Services
- COUNTRIES/AREAS DEPLOYED: United States
- COMPANY HEADQUARTERS LOCATION: United States
3.4 RESEARCHER
The Michigan State Police Michigan Cyber Command Center (MC3) reported these vulnerabilities to CISA.
4. MITIGATIONS
Motorola Solutions recommends the following for each identified vulnerability:
CVE-2024-38279:
- Use secure boot implementation with an edit-resistant GRUB partition.
- Additional mitigation consists in limiting the physical access to the device by following the best practices for device mounting.
Edit-resistant grub partition has been remediated for all vulnerable systems. Motorola Solutions
will release a secure boot implementation in Fall 2024. All customers will receive the update
through OTA (over the air) mechanisms. No further actions are required by customers.
CVE-2024-38280:
- Apply encryption to all Criminal Justice Information (CJI) data.
- Apply full disk encryption with LUKS encryption standards and add password protection
to the GRUB Bootloader. - Perform column-level encryption for sensitive data in the database.
All devices shipped after May 10, 2024 are already using full disk encryption. All devices that
are not able to have full disk encryption applied have had all CJI data encrypted. No further
actions are required by customers.
CVE-2024-38281:
- Remove the hard-coded credential to access the wireless access point and disable the
access point if not needed. - Set a unique SSID and password if the access point is needed.
Motorola Solutions has already remediated this vulnerability for all vulnerable systems. No further actions are required by customers.
CVE-2024-38282:
- Remove the hard coded credentials.
- Use a unique CJIS compliant password per device.
Motorola Solutions has already remediated this vulnerability for all vulnerable systems. No further actions are required by customers.
CVE-2024-38283:
- Remove the hotlist data from the device.
Motorola Solutions has already remediated this vulnerability for all vulnerable systems. No
further actions are required by customers.
CVE-2024-38284:
- Delete the log files.
- Install updated software not logging the credentialed web request.
Motorola Solutions has already remediated this vulnerability for all vulnerable systems. No further actions are required by customers.
CVE-2024-38285:
- Delete the log files.
Motorola Solutions has already remediated this vulnerability for all vulnerable systems. No further actions are required by customers.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
5. UPDATE HISTORY
- June 13, 2024: Initial Publication
Siemens Mendix Applications
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v4 7.4
- ATTENTION: Exploitable remotely
- Vendor: Siemens
- Equipment: Mendix Applications
- Vulnerability: Improper Privilege Management
2. RISK EVALUATION
Successful exploitation requires to guess the identification of a target role which contains the elevated access rights.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Siemens products, are affected:
- Siemens Mendix Applications using Mendix 9: Versions prior to V9.24.22 and after V9.3.0
- Siemens Mendix Applications using Mendix 10: Versions prior to V10.11.0
- Siemens Mendix Applications using Mendix 10 (V10.6): Versions prior V10.6.9
3.2 Vulnerability Overview
3.2.1 IMPROPER PRIVILEGE MANAGEMENT CWE-269
Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights.
CVE-2024-33500 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:N).
A CVSS v4 score has also been calculated for CVE-2024-33500. A base score of 7.4 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N).
3.3 BACKGROUND
- CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities, Critical Manufacturing, Defense Industrial Base, Energy, Financial Services, Government Facilities, Healthcare and Public Health, Transportation Systems
- COUNTRIES/AREAS DEPLOYED: Worldwide
- COMPANY HEADQUARTERS LOCATION: Germany
3.4 RESEARCHER
Achmea Security Assessment Team reported this vulnerability to Siemens.
4. MITIGATIONS
Siemens recommends users update the product to following versions:
- Mendix Applications using Mendix 9: Update to V9.24.22 or later version
- Mendix Applications using Mendix 10: Update to V10.11.0 or later version
-
Mendix Applications using Mendix 10 (V10.6): Update to V10.6.9 or later version
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- Set the runtime setting StrictReferenceChecks to false; note however, that this comes at the price of making the reference checks less secure
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-540640 in HTML and CSAF.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open attachments in unsolicited email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
5. UPDATE HISTORY
- June 13, 2024: Initial Publication
Siemens ST7 ScadaConnect
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v3 8.2
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: ST7 ScadaConnect
- Vulnerabilities: Integer Overflow or Wraparound, Double Free, Improper Certificate Validation, Inefficient Regular Expression Complexity, Improper Check for Unusual or Exceptional Conditions, Improper Input Validation, NULL Pointer Dereference, Missing Encryption of Sensitive Data, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Resource Consumption
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to disclose information, cause a denial-of-service (DoS) condition, or execute arbitrary code.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
The following Siemens products, are affected:
- Siemens ST7 ScadaConnect (6NH7997-5DA10-0AA0): Versions prior to 1.1
3.2 Vulnerability Overview
3.2.1 INTEGER OVERFLOW OR WRAPAROUND CWE-190
An issue was discovered in libxml2 before 2.10.3. When parsing a multi-gigabyte XML document with the XML_PARSE_HUGE parser option enabled, several integer counters can overflow. This results in an attempt to access an array at a negative 2GB offset, typically leading to a segmentation fault.
CVE-2022-40303 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
3.2.2 DOUBLE FREE CWE-415
An issue was discovered in libxml2 before 2.10.3. Certain invalid XML entity definitions can corrupt a hash table key, potentially leading to subsequent logic errors. In one case, a double-free can be provoked.
CVE-2022-40304 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.3 IMPROPER CERTIFICATE VALIDATION CWE-295
A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.
CVE-2023-0464 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
3.2.4 IMPROPER CERTIFICATE VALIDATION CWE-295
Applications that use a non-default option when verifying certificates may be vulnerable to an attack from a malicious CA to circumvent certain checks. Invalid certificate policies in leaf certificates are silently ignored by OpenSSL and other certificate policy checks are skipped for that certificate. A malicious CA could use this to deliberately assert invalid certificate policies in order to circumvent policy checking on the certificate altogether. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.
CVE-2023-0465 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).
3.2.5 IMPROPER CERTIFICATE VALIDATION CWE-295
The function X509_VERIFY_PARAM_add0_policy() is documented to implicitly enable the certificate policy check when doing certificate verification. However the implementation of the function does not enable the check which allows certificates with invalid or incorrect policies to pass the certificate verification.As suddenly enabling the policy check could break existing deployments it was decided to keep the existing behavior of the X509_VERIFY_PARAM_add0_policy()function.Instead the applications that require OpenSSL to perform certificate policy check need to use X509_VERIFY_PARAM_set1_policies() or explicitly enable the policy check by calling X509_VERIFY_PARAM_set_flags() with the X509_V_FLAG_POLICY_CHECK flag argument.Certificate policy checks are disabled by default in OpenSSL and are not commonly used by applications.
CVE-2023-0466 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).
3.2.6 INEFFICIENT REGULAR EXPRESSION COMPLEXITY CWE-1333
Issue summary: Checking excessively long DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial-of-Service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus (‘p’ parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial-of-Service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the ‘-check’ option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.
CVE-2023-3446 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
3.2.7 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754
Issue summary: Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial-of-Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn’t make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn’t check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial-of-Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the “-pubcheck” option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.
CVE-2023-5678 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
3.2.8 IMPROPER INPUT VALIDATION CWE-20
.NET and Visual Studio Remote Code Execution Vulnerability
CVE-2023-21808 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.9 IMPROPER INPUT VALIDATION CWE-20
.NET, .NET Framework, and Visual Studio Remote Code Execution Vulnerability
CVE-2023-24895 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.10 IMPROPER INPUT VALIDATION CWE-20
.NET, .NET Framework, and Visual Studio Remote Code Execution Vulnerability
CVE-2023-24897 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.11 IMPROPER INPUT VALIDATION CWE-20
.NET, .NET Framework, and Visual Studio Elevation of Privilege Vulnerability
CVE-2023-24936 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
3.2.12 IMPROPER INPUT VALIDATION CWE-20
.NET DLL Hijacking Remote Code Execution Vulnerability
CVE-2023-28260 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
3.2.13 NULL POINTER DEREFERENCE CWE-476
In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segfault. This occurs in xmlSchemaFixupComplexType in xmlschemas.c.
CVE-2023-28484 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).
3.2.14 IMPROPER INPUT VALIDATION CWE-20
.NET, .NET Framework, and Visual Studio Denial-of-Service Vulnerability
CVE-2023-29331 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
3.2.15 DOUBLE FREE CWE-415
An issue was discovered in libxml2 before 2.10.4. When hashing empty dict strings in a crafted XML document, xmlDictComputeFastKey in dict.c can produce non-deterministic values, leading to various logic and memory errors, such as a double free. This behavior occurs because there is an attempt to use the first byte of an empty string, and any value is possible (not solely the ‘