Siemens SINUMERIK

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable from adjacent network/low attack complexity
  • Vendor: Siemens
  • Equipment: SINUMERIK
  • Vulnerability: Authentication Bypass Using an Alternate Path or Channel

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • SINUMERIK 828D PPU.4: Versions prior to V4.95 SP5
  • SINUMERIK 828D PPU.5: Versions prior to V5.25 SP1
  • SINUMERIK 840D sl: Versions prior to V4.95 SP5
  • SINUMERIK MC: Versions prior to V1.25 SP1
  • SINUMERIK MC V1.15: Versions prior to V1.15 SP5
  • SINUMERIK ONE: Versions prior to V6.25 SP1
  • SINUMERIK ONE V6.15: Versions prior to V6.15 SP5

3.2 VULNERABILITY OVERVIEW

3.2.1 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288

The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

CVE-2025-40743 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L).

A CVSS v4 score has also been calculated for CVE-2025-40743. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Apply Defense-in-Depth.
  • Close VNC port on X130 via HMI setting.
  • Set VNC Password on X120 and X130.
  • Change TCU.ini setting to “ExternalViewerReqTimeoutMode=0”.
  • SINUMERIK MC V1.15: Update to V1.15 SP5 or later version.
  • SINUMERIK MC: Update to V1.25 SP1 or later version.
  • SINUMERIK 840D sl: Update to V4.95 SP5 or later version.
  • SINUMERIK 828D PPU.4: Update to V4.95 SP5 or later version.
  • SINUMERIK 828D PPU.5: Update to V5.25 SP1 or later version.
  • SINUMERIK ONE V6.15: Update to V6.15 SP5 or later version.
  • SINUMERIK ONE: Update to V6.25 SP1 or later version.
  • Updated software version can be obtained from Siemens customer support or a local partner.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-177847 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens SSA-177847

Siemens SINEC Traffic Analyzer

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINEC Traffic Analyzer
  • Vulnerabilities: NULL Pointer Dereference, Use After Free, Uncontrolled Resource Consumption, Execution with Unnecessary Privileges, Exposure of Sensitive Information to an Unauthorized Actor, Irrelevant Code, Channel Accessible by Non-Endpoint

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or gain elevated access and access to sensitive resources.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports the following products are affected:

  • Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0): All versions prior to 3.0 (CVE-2024-24989, CVE-2024-24990, CVE-2025-40766, CVE-2025-40767, CVE-2025-40768, CVE-2025-40769)
  • Siemens SINEC Traffic Analyzer (6GK8822-1BG01-0BA0): All versions (CVE-2025-40770)

3.2 VULNERABILITY OVERVIEW

3.2.1 NULL POINTER DEREFERENCE CWE-476

When NGINX Plus or NGINX OSS are configured to use the HTTP/3 QUIC module, undisclosed requests can cause NGINX worker processes to terminate. Note: The HTTP/3 QUIC module is not enabled by default and is considered experimental. For more information, refer to Support for QUIC and HTTP/3 https://nginx.org/en/docs/quic.html. Note: Software versions that have reached End of Technical Support (EoTS) are not evaluated.

CVE-2024-24989 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.2 USE AFTER FREE CWE-416

When NGINX Plus or NGINX OSS are configured to use the HTTP/3 QUIC module, undisclosed requests can cause NGINX worker processes to terminate. Note: The HTTP/3 QUIC module is not enabled by default and is considered experimental. For more information, refer to Support for QUIC and HTTP/3 https://nginx.org/en/docs/quic.html. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

CVE-2024-24990 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.3 UNCONTROLLED RESOURCE CONSUMPTION CWE-400

The affected application runs docker containers without adequate resource and security limitations. This could allow an attacker to perform a denial-of-service (DoS) attack.

CVE-2025-40766 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40766. A base score of 6.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.4 EXECUTION WITH UNNECESSARY PRIVILEGES CWE-250

The affected application runs docker containers without adequate security controls to enforce isolation. This could allow an attacker to gain elevated access, potentially accessing sensitive host system resources.

CVE-2025-40767 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40767. A base score of 8.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.2.5 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200

The affected application exposes an internal service port to be accessible from outside the system. This could allow an unauthorized attacker to access the application.

CVE-2025-40768 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40768. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N).

3.2.6 IRRELEVANT CODE CWE-1164

The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.

CVE-2025-40769 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40769. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.7 CHANNEL ACCESSIBLE BY NON-ENDPOINT CWE-300

The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.

CVE-2025-40770 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40770. A base score of 7.5 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens ProductCERT reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • (CVE-2024-24989, CVE-2024-24990, CVE-2025-40766, CVE-2025-40767, CVE-2025-40768, CVE-2025-40769) SINEC Traffic Analyzer (6GK8822-1BG01-0BA0): Update to V3.0 or later version
  • (CVE-2025-40770) SINEC Traffic Analyzer (6GK8822-1BG01-0BA0): Currently no fix is available

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-517338 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens ProductCERT SSA-517338

Siemens SIMATIC RTLS Locating Manager

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.4
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SIMATIC RTLS Locating Manager
  • Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an authenticated remote attacker to execute arbitrary code with high privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • SIMATIC RTLS Locating Manager: Versions prior to V3.2

3.2 VULNERABILITY OVERVIEW

3.2.1 IMPROPER INPUT VALIDATION CWE-20

Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with ‘NT Authority/SYSTEM’ privileges.

CVE-2025-40746 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40746. A base score of 9.4 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-493787 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens ProductCERT SSA-493787

Siemens SIPROTEC 4 and SIPROTEC 4 Compact

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SIPROTEC 4 and SIPROTEC 4 Compact
  • Vulnerability: Improper Check for Unusual or Exceptional Conditions

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • SIPROTEC 4 6MD61: All versions
  • SIPROTEC 4 7SJ62: All versions
  • SIPROTEC 4 7SJ63: All versions
  • SIPROTEC 4 7SJ64: All versions
  • SIPROTEC 4 7SJ66: All versions
  • SIPROTEC 4 7SS52: All versions
  • SIPROTEC 4 7ST6: All versions
  • SIPROTEC 4 7UM61: All versions
  • SIPROTEC 4 7UM62: All versions
  • SIPROTEC 4 7UT63: All versions
  • SIPROTEC 4 7UT612: All versions
  • SIPROTEC 4 6MD63: All versions
  • SIPROTEC 4 7UT613: All versions
  • SIPROTEC 4 7VE6: All versions
  • SIPROTEC 4 7VK61: All versions
  • SIPROTEC 4 7VU683: All versions
  • SIPROTEC 4 Compact 7RW80: All versions
  • SIPROTEC 4 Compact 7SD80: All versions
  • SIPROTEC 4 Compact 7SJ80: All versions
  • SIPROTEC 4 Compact 7SJ81: All versions
  • SIPROTEC 4 Compact 7SK80: All versions
  • SIPROTEC 4 Compact 7SK81: All versions
  • SIPROTEC 4 6MD66: All versions
  • SIPROTEC 4 6MD665: All versions
  • SIPROTEC 4 7SA6: Versions prior to V4.78
  • SIPROTEC 4 7SA522: All versions
  • SIPROTEC 4 7SD5: Versions prior to V4.78
  • SIPROTEC 4 7SD610: Versions prior to V4.78
  • SIPROTEC 4 7SJ61: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial-of-service-condition. To restore normal operations, the devices need to be restarted.

CVE-2024-52504 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-52504. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • SIPROTEC 4 6MD61, SIPROTEC 4 6MD63, SIPROTEC 4 6MD66, SIPROTEC 4 6MD665, SIPROTEC 4 7SA522, SIPROTEC 4 7SJ61, SIPROTEC 4 7SJ62, SIPROTEC 4 7SJ63, SIPROTEC 4 7SJ64, SIPROTEC 4 7SS52, SIPROTEC 4 7ST6, SIPROTEC 4 7UM61, SIPROTEC 4 7UM62, SIPROTEC 4 7UT63, SIPROTEC 4 7UT612, SIPROTEC 4 7UT613, SIPROTEC 4 7VE6, SIPROTEC 4 7VK61, SIPROTEC 4 7VU683, SIPROTEC 4 Compact 7RW80, SIPROTEC 4 Compact 7SD80, SIPROTEC 4 Compact 7SJ80, SIPROTEC 4 Compact 7SJ81, SIPROTEC 4 Compact 7SK80, SIPROTEC 4 Compact 7SK81: Currently no fix is planned
  • SIPROTEC 4 7SJ66: Currently no fix is available
  • SIPROTEC 4 7SA6: Update to V4.78 or later version
  • SIPROTEC 4 7SD5: Update to V4.78 or later version
  • SIPROTEC 4 7SD610: Update to V4.78 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-400089 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens ProductCERT SSA-400089

Siemens RUGGEDCOM ROX II

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.6
  • ATTENTION: Low Attack Complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM ROX II family
  • Vulnerability: Authentication Bypass Using an Alternate Path or Channel

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a local attacker to bypass authentication and access a root shell on the device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • RUGGEDCOM ROX MX5000: All versions
  • RUGGEDCOM ROX RX1536: All versions
  • RUGGEDCOM ROX RX5000: All versions
  • RUGGEDCOM ROX MX5000RE: All versions
  • RUGGEDCOM ROX RX1400: All versions
  • RUGGEDCOM ROX RX1500: All versions
  • RUGGEDCOM ROX RX1501: All versions
  • RUGGEDCOM ROX RX1510: All versions
  • RUGGEDCOM ROX RX1511: All versions
  • RUGGEDCOM ROX RX1512: All versions
  • RUGGEDCOM ROX RX1524: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288

Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.

CVE-2025-40761 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-40761. A base score of 8.6 has been calculated; the CVSS vector string is (CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Currently no fix is available
  • RUGGEDCOM ROX RX1400: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. SeeSec. 5.9.3 for more details
  • RUGGEDCOM ROX RX1500, RUGGEDCOM ROX RX1501, RUGGEDCOM ROX RX1510, RUGGEDCOM ROX RX1511, RUGGEDCOM ROX RX1512, RUGGEDCOM ROX RX1524, RUGGEDCOM ROX RX1536: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. See Sec. 5.9.3 for more details
  • RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, RUGGEDCOM ROX RX5000: Ensure a secure boot password is set as described in the configuration manual to prevent unauthorized access to BIST mode. See Sec. 5.9.3 for more details

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-094954 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens SSA-094954

Siemens COMOS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.2
  • ATTENTION: Low Attack Complexity
  • Vendor: Siemens
  • Equipment: COMOS
  • Vulnerability: Out-of-bounds Write

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a crash, potentially enabling a denial-of-service attack (Crash, Exit, or Restart) or possible code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens COMOS: all versions prior to V10.6

3.2 VULNERABILITY OVERVIEW

3.2.1 OUT-OF-BOUNDS WRITE CWE-787

Out-of-bounds Write vulnerability was discovered in Open Design Alliance Drawings SDK before 2025.10. Reading crafted DWF file and missing proper checks on received SectionIterator data can trigger an unhandled exception. This can allow attackers to cause a crash, potentially enabling a denial-of-service attack (Crash, Exit, or Restart) or possible code execution.

CVE-2024-8894 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens ProductCERT reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • COMOS: Ensure all files imported into the affected product originate from a trusted source and are transmitted over secure channels
  • COMOS: Update to V10.6 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-769791 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication of Siemens ProductCERT SSA-769791

Rockwell Automation ControlLogix Ethernet Modules

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: ControlLogix Ethernet Modules
  • Vulnerability: Initialization of a Resource with an Insecure Default

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow remote attackers to perform memory dumps, modify memory, and control execution flow.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Rockwell Automation ControlLogix Ethernet Modules are affected:

  • 1756-EN2T/D: Version 11.004 or below
  • 1756-EN2F/C: Version 11.004 or below
  • 1756-EN2TR/C: Version 11.004 or below
  • 1756-EN3TR/B: Version 11.004 or below
  • 1756-EN2TP/A: Version 11.004 or below

3.2 VULNERABILITY OVERVIEW

3.2.1 Initialization of a Resource with an Insecure Default CWE-1188

Rockwell Automation ControlLogix Ethernet Modules are vulnerable to a security issue where the web-based debugger agent is enabled by default on released devices. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.

CVE-2025-7353 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2025-7353. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Energy, Critical Manufacturing, Food and Agriculture, Transportation Systems, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation recommends that ControlLogix Ethernet Module users update to Version 12.001 if possible. If users are unable to upgrade to Version 12.001, security best practices should be applied.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • August 14, 2025: Initial Republication

CISA and Partners Release Asset Inventory Guidance for Operational Technology Owners and Operators

CISA, along with the National Security Agency, the Federal Bureau of Investigation, Environmental Protection Agency, and several international partners, released comprehensive guidance to help operational technology (OT) owners and operators across all critical infrastructure sectors create and maintain OT asset inventories and supplemental taxonomies. 

An asset inventory is a regularly updated, structured list of an organization’s systems, hardware, and software. It includes a categorization system—a taxonomy—that classifies assets based on their importance and function. This guidance explains how OT owners and operators can create, maintain, and use asset inventories and taxonomies to identify and safeguard their critical assets. 

Following this guidance, organizations may gain deeper insights into their architecture, optimize their defenses, better assess and reduce cybersecurity risk in their environments, and enhance incident response planning to ensure service continuity.

CISA Issues ED 25-02: Mitigate Microsoft Exchange Vulnerability

Today, CISA issued Emergency Directive (ED) 25-02: Mitigate Microsoft Exchange Vulnerability in response to CVE-2025-53786, a vulnerability in Microsoft Exchange server hybrid deployments.  

ED 25-02 directs all Federal Civilian Executive Branch (FCEB) agencies with Microsoft Exchange hybrid environments to implement required mitigations by 9:00 AM EDT on Monday, August 11, 2025

This vulnerability presents significant risk to all organizations operating Microsoft Exchange hybrid-joined configurations that have not yet implemented the April 2025 patch guidance.

Although this directive is only for FCEB agencies, CISA strongly encourages all organizations to address this vulnerability. For additional details, see CISA’s Alert: Microsoft Releases Guidance on Vulnerability (CVE-2025-53786) in Hybrid Exchange Deployments.