Hitachi Energy TRO600

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Hitachi Energy
  • Equipment: TRO600 Series
  • Vulnerabilities: Command Injection, Improper Removal of Sensitive Information Before Storage or Transfer

2. RISK EVALUATION

Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensively than the write privilege intends. Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Profile files provide potential attackers valuable configuration information about the Tropos network. Profiles can only be exported by authenticated users with write access.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Hitachi Energy are affected:

  • Hitachi Energy TRO600 series firmware versions: 9.0.1.0 – 9.2.0.0 (CVE-2024-41156)
  • Hitachi Energy TRO600 series firmware versions: 9.1.0.0 – 9.2.0.0 (CVE-2024-41153)

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive than what the write privilege intends.

CVE-2024-41153 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.2 IMPROPER REMOVAL OF SENSITIVE INFORMATION BEFORE STORAGE OR TRANSFER CWE-212

Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Profile files provide potential attackers valuable configuration information about the Tropos network. Profiles can only be exported by authenticated users with write access.

CVE-2024-41156 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Riley Barello-Myers, Idaho National Lab – CyTRICS reported these vulnerabilities to Hitachi Energy.

4. MITIGATIONS

Hitachi Energy has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • (CVE-2024-41153) Hitachi Energy TRO600 series firmware versions from 9.1.0.0 to 9.2.0.0 (Edge computing functionality): Update to version 9.2.0.5
  • (CVE-2024-41156) Hitachi Energy TRO600 series firmware versions from 9.0.1.0 to 9.2.0.0 (Configuration utility): Update to version 9.2.0.5

Hitachi Energy has provided the additional following security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network:

  • Physically protect process control systems from direct access by unauthorized personnel.
  • Do not connect directly to the Internet.
  • Separate from other networks by means of a firewall system that has a minimal number of ports exposed.
  • Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails.
  • Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

For more details, refer to the “Configuration Guide” document for the respective TRO600 series router version.

For more information, see Hitachi Energy’s security advisory 8DBD000147

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • November 12, 2024: Initial Publication

Citrix Releases Security Updates for NetScaler and Citrix Session Recording

Citrix released security updates to address multiple vulnerabilities in NetScaler ADC, NetScaler Gateway, and Citrix Session Recording. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system.  

 CISA encourages users and administrators to review the following and apply necessary updates:   

Ivanti Releases Security Updates for Multiple Products

Ivanti released security updates to address vulnerabilities in Ivanti Endpoint Manager (EPM), Ivanti Avalanche, Ivanti Connect Secure, Ivanti Policy Secure, and Ivanti Security Access Client.

CISA encourages users and administrators to review the following Ivanti security advisories and apply the necessary guidance and updates:

CISA Adds Five Known Exploited Vulnerabilities to Catalog

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2021-26086 Atlassian Jira Server and Data Center Path Traversal Vulnerability
  • CVE-2014-2120 Cisco Adaptive Security Appliance (ASA) Cross-Site Scripting (XSS) Vulnerability
  • CVE-2021-41277 Metabase GeoJSON API Local File Inclusion Vulnerability
  • CVE-2024-43451 Microsoft Windows NTLMv2 Hash Disclosure Spoofing Vulnerability
  • CVE-2024-49039 Microsoft Windows Task Scheduler Privilege Escalation Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Rockwell Automation FactoryTalk View ME

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.0
  • ATTENTION: Low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: FactoryTalk View ME
  • Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a local low-privileged user to escalate their privileges by changing the macro to execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Rockwell Automation reports that the following versions of FactoryTalk Software are affected:

  • FactoryTalk View ME, when using default folder privileges: v14.0 and prior

3.2 Vulnerability Overview

3.2.1 Improper Input Validation CWE-20

A remote code execution vulnerability exists in FactoryTalk View ME. The vulnerability allows users to save projects within the public directory allowing anyone with local access to modify and/or delete files. Additionally, a malicious user could potentially leverage this vulnerability to escalate their privileges by changing the macro to execute arbitrary code.

CVE-2024-37365 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated forCVE-2024-37365. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation has corrected this problem in V15.0.

Rockwell Automation encourages users of the affected software who are not able to upgrade to one of the corrected versions to apply the following risk mitigations where possible.

  • To enhance security and help prevent unauthorized modifications to HMI project files, harden the Windows OS by removing the INTERACTIVE group from the folder’s security properties.
  • Add specific users or user groups and assign their permissions to this folder using the least privileges principle. Users with read-only permission can still test run and run the FactoryTalk View ME Station.
  • Guidance can be found in FactoryTalk View ME v14 Help topic: “HMI projects folder settings”. It can be opened through the FactoryTalk View ME Studio menu “helpContentsFactoryTalk View ME HelpCreate a Machine Edition application->Open applications->HMI project folder settings”.
  • Security Best Practices

For more information, see Rockwell Automation’s security advisory

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • November 12, 2024: Initial Publication

Bosch Rexroth IndraDrive

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Bosch Rexroth
  • Equipment: IndraDrive
  • Vulnerability: Uncontrolled Resource Consumption

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Bosch Rexroth reports that the following versions of IndraDrive, servo drive system, are affected:

  • Bosch Rexroth AG IndraDrive FWA-INDRV*MP*: 17VRS < 20V36

3.2 Vulnerability Overview

3.2.1 Uncontrolled Resource Consumption CWE-400

A vulnerability in the PROFINET stack implementation of the IndraDrive of Bosch Rexroth allows an attacker to cause a denial-of-service, rendering the device unresponsive by sending arbitrary UDP messages.

CVE-2024-48989 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-48989. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Roni Gavrilov from OTORIO reported this vulnerability to CISA.

4. MITIGATIONS

Bosch Rexroth has fixed this vulnerability starting with FWA-INDRV-MP-20V36. Bosch Rexroth recommends updating as soon as possible.

In use cases in which a device update is not possible or not feasible, Bosch Rexroth recommends compensatory measures which prevent or at least complicate taking advantage of the vulnerability. Always define such compensatory measures individually, in the context of the operational environment.

Some possible measures are described in “Security Manual Electric Drives and Controls”, like network segmentation. In general, it is highly recommended to implement the measures described in “Security Manual Drives and Controls”.

For more information, refer to the Bosch PSIRT Security Advisory BOSCH-SA-2584444

Please contact the Bosch PSIRT if you have feedback, comments, or additional information about this vulnerability at: psirt@bosch.com .

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • November 7, 2024: Initial Publication