CISA Secure by Design Alert Urges Manufacturers to Eliminate Default Passwords

Today, CISA published guidance on How Manufacturers Can Protect Customers by Eliminating Default Passwords as a part of our new Secure by Design (SbD) Alert series.

This SbD Alert urges technology manufacturers to proactively eliminate the risk of default password exploitation by implementing principles one and three of the joint guidance, Shifting the Balance of Cybersecurity Risk: Principles and Approaches for Secure by Design Software:

  • Take ownership of customer security outcomes.
  • Build organizational structure and leadership to achieve these goals. 

By implementing these two principles in their design, development, and delivery processes, software manufactures will prevent exploitation of static default passwords in their customers’ systems. CISA urges technology manufacturers to read and implement the guidance in this second SbD Alert in our new series that focuses on how vendor decisions can reduce harm at a global scale.

CISA Releases Advisory on Cyber Resilience for the HPH Sector

Today, CISA released a Cybersecurity Advisory, Enhancing Cyber Resilience: Insights from the CISA Healthcare and Public Health Sector Risk and Vulnerability Assessment, that details findings from our risk and vulnerability assessments of a Health and Public Health (HPH) Sector organization.

CISA encourages all critical infrastructure organizations as well as software manufacturers to review the advisory and apply recommendations. The recommendations detail how organizations can harden networks to improve cyber resilience and reduce the likelihood of domain compromise.

CISA encourages HPH Sector organizations to visit our Healthcare and Public Health Cybersecurity page for the new HPH Cybersecurity Toolkit.

Siemens SINUMERIK

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINUMERIK MC, SINUMERIK ONE
  • Vulnerability: Use After Free

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • SINUMERIK MC: All versions
  • SINUMERIK ONE: All versions

3.2 Vulnerability Overview

3.2.1 USE AFTER FREE CWE-416

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial-of-service condition. A restart is needed to restore normal operations.

CVE-2023-46156 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Expose port 102/tcp of the integrated S7-1500 CPU only to trusted network environments

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-280603 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

Siemens Simantic S7-1500 CPU family

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: Simantic S7-1500 CPU family
  • Vulnerability: Use After Free

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0): All versions prior to V3.1.0
  • SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): All versions prior to V3.1.0
  • SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): All versions
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0): All versions
  • SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0): All versions
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0):All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0): All versions
  • SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0): All versions prior to V3.1.0
  • SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0): All versions
  • SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0): All versions
  • SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0): All versions
  • SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0): All versions
  • SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0): All versions
  • SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0): All versions
  • SIMATIC S7-1500 Software Controller: All versions
  • SIMATIC S7-PLCSIM Advanced: All versions prior to V6.0
  • SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0): All versions
  • SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0): All versions
  • SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0): All versions
  • SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0): All versions
  • SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0): All versions
  • SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0): All versions
  • SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0): All versions
  • SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0): All versions
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0): All versions
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0): All versions
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0): All versions
  • SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0): All versions
  • SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0): All versions
  • SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0): All versions
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0): All versions
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0): All versions
  • SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0): All versions
  • SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0): All versions prior to V3.1.0
  • SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0): All versions prior to V3.1.0
  • SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0): All versions prior to V3.1.0
  • SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0): All versions

3.2 Vulnerability Overview

3.2.1 USE AFTER FREE CWE-416

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial-of-service condition. A restart is needed to restore normal operations.

CVE-2023-46156 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk.

For the following devices, Update to V3.1.0 or later version:

  • SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0)
  • SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0)

For the following devices, limit access to port 102/TCP to trusted users and systems only:

  • SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0)
  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0)
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ00-0AB0)
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK00-0AB0)
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0)
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0)
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0)
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0)
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK00-0AB0)
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0)
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0)
  • SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0)
  • SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0)
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0)
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0)
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK00-0AB0)
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0)
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK00-0AB0)
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0)
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL00-0AB0)
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0)
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0)
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL00-0AB0)
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0)
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0)
  • SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0)
  • SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0)
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM00-0AB0)
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0)
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0)
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM00-0AB0)
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0)
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0)
  • SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0)
  • SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0)
  • SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0)
  • SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0)
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN00-0AB0)
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0)
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0)
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN00-0AB0)
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0)
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0)
  • SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0)
  • SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0)
  • SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0)
  • SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0)
  • SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0)
  • SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0)
  • SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0)
  • SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0)
  • SIMATIC S7-1500 Software Controller
  • SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0)
  • SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0)
  • SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0)
  • SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0)
  • SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0)
  • SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0)
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK00-2AB0)
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0)
  • SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0)
  • SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0)
  • SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0)
  • SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0)
  • SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0)
  • SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0)
  • SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK00-2AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0)
  • SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0)
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK00-2AB0)
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0)
  • SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0)
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL00-2AB0)
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0)
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0)
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0)
  • SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0)
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL00-2AB0)
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0)
  • SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0)
  • SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0)
  • SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0)
  • SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0)
  • SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0)
  • SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0)
  • SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-2AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN00-7AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0)
  • SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0)
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN00-2AB0)
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0)
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0)
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0)
  • SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0)
  • SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0)
  • SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0)

For the following devices, Update to V3.1.0 or later version:

  • SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0)
  • SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0)
  • SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0)
  • SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CL03-0AB0)
  • SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0)
  • SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0)
  • SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0)
  • SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CM03-0AB0)
  • SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0)
  • SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0)
  • SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0)
  • SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0)
  • SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0)
  • SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0)
  • SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0)
  • SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0)
  • SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0)
  • SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0)
  • SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0)
  • SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0)
  • SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0)
  • SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0)
  • SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0)
  • SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0)
  • SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0)
  • SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0)
  • SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP01-0AB0)
  • SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0)
  • SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0)
  • SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)
  • SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)
  • SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0)
  • SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)
  • SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)
  • SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0)
  • SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0)
  • SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)
  • SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0)

For the following devices, Update to V6.0 or later version:

  • SIMATIC S7-PLCSIM Advanced

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-592380 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

Siemens OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINUMERIK MC, SINUMERIK ONE
  • Vulnerability: Integer Overflow or Wraparound

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • SINUMERIK MC: All versions prior to V1.22
  • SINUMERIK ONE: All versions prior to V6.22

3.2 Vulnerability Overview

3.2.1 INTEGER OVERFLOW OR WRAPAROUND CWE-190

The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial-of-service condition by sending a specially crafted certificate.

CVE-2023-28831 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

SINUMERIK MC:

  • Expose the OPC UA interface of the integrated S7-1500 CPU only to trusted network environments
  • Update to V1.22 or later version

SINUMERIK ONE:

  • Expose the OPC UA interface of the integrated S7-1500 CPU only to trusted network environments
  • Update to V6.22 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-118850 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

Siemens User Management Component (UMC)

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: User Management Component (UMC)
  • Vulnerabilities: Permissive Cross-domain Policy with Untrusted Domains, Cross-site Scripting, Classic Buffer Overflow, Improper Input Validation

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could lead to a restart of the UMC server.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports the following products are affected:

  • Opcenter Quality: all versions
  • SIMATIC PCS neo: versions prior to v4.1
  • SINUMERIK Integrate RunMyHMI /Automotive: all versions
  • Totally Integrated Automation Portal (TIA Portal) v14: all versions
  • Totally Integrated Automation Portal (TIA Portal) v15.1: all versions
  • Totally Integrated Automation Portal (TIA Portal) v16: all versions
  • Totally Integrated Automation Portal (TIA Portal) v17: all versions
  • Totally Integrated Automation Portal (TIA Portal) v18: versions prior to V18 update 3

3.2 Vulnerability Overview

3.2.1 PERMISSIVE CROSS-DOMAIN POLICY WITH UNTRUSTED DOMAINS CWE-942

When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.

CVE-2023-46281 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L).

3.2.2 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (‘CROSS-SITE SCRIPTING’) CWE-79

A reflected cross-site scripting vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

CVE-2023-46282 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L).

3.2.3 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (‘CLASSIC BUFFER OVERFLOW’) CWE-120

The affected application contains an out-of-bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

CVE-2023-46283 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.4 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT (‘CLASSIC BUFFER OVERFLOW’) CWE-120

The affected application contains an out-of-bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

CVE-2023-46284 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.5 IMPROPER INPUT VALIDATION CWE-20

The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a denial-of-service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

CVE-2023-46285 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has released updates for several affected products and recommends users update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Do not access links from untrusted sources.
  • If only one UMC server is used, block access to port 4002/tcp e.g. with an external firewall.
  • If only one RT server is used, block access to port 4004/tcp e.g. with an external firewall. If the deployment contains no RT-Servers, block the port in the local firewall.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-999588 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

Siemens SINEC INS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINEC INS
  • Vulnerabilities: Improper Certificate Validation, Improper Input Validation, Improper Neutralization of Special Elements used in an OS Command (‘OS Command Injection’), Unexpected Status Code or Return Value, Missing Report of Error Condition, Improper Check for Unusual or Exceptional Conditions

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition, intercept credentials, or escalate privileges on the affected device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • SINEC INS: Versions prior to V1.0 SP2 Update 2

3.2 Vulnerability Overview

3.2.1 IMPROPER CERTIFICATE VALIDATION CWE-295

A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.

CVE-2023-0464 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.2 IMPROPER INPUT VALIDATION CWE-20

libcurl would reuse a previously created connection even when an SSH related option had been changed that should have prohibited reuse. libcurl keeps previously used connections in a connection pool for subsequent transfers to reuse if one of them matches the setup. However, two SSH settings were left out from the configuration match checks, making them match too easily.

CVE-2023-27538 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.2.3 IMPROPER CERTIFICATE VALIDATION CWE-295

Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges.

CVE-2023-48427 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.4 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND (‘OS COMMAND INJECTION’) CWE-78

The radius configuration mechanism of affected products does not correctly check uploaded certificates. A malicious admin could upload a crafted certificate resulting in a denial-of-service condition or potentially issue commands on system level.

CVE-2023-48428 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.5 UNEXPECTED STATUS CODE OR RETURN VALUE CWE-394

The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.

CVE-2023-48429 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L).

3.2.6 MISSING REPORT OF ERROR CONDITION CWE-392

The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

CVE-2023-48430 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L).

3.2.7 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).

CVE-2023-48431 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • SINEC INS: Update to V1.0 SP2 Update 2 or later version
  • SINEC INS: Restrict access to application webserver for trusted users only

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-077170 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

Siemens SCALANCE and RUGGEDCOM M-800/S615 Family

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SCALANCE M-800/S615 Family
  • Vulnerabilities: Acceptance of Extraneous Untrusted Data With Trusted Data, OS Command Injection

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker with administrative privileges to execute arbitrary code on the affected device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2): All versions prior to V7.2.2
  • RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2): All versions prior to V7.2.2
  • SCALANCE M804PB (6GK5804-0AP00-2AA2): All versions prior to V7.2.2
  • SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2): All versons prior to V7.2.2
  • SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2): All versions prior to V7.2.2
  • SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2): All versions prior to V7.2.2
  • SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2): All versions prior to V7.2.2
  • SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2): All versions prior to V7.2.2
  • SCALANCE M874-2 (6GK5874-2AA00-2AA2): All versions prior to V7.2.2
  • SCALANCE M874-3 (6GK5874-3AA00-2AA2): All versions prior to V7.2.2
  • SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2): All versions prior to V7.2.2
  • SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2): All versions prior to V7.2.2
  • SCALANCE M876-4 (6GK5876-4AA10-2BA2): All versions prior to V7.2.2
  • SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2): All versions prior to V7.2.2
  • SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2): All versions prior to V7.2.2
  • SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1): All versions prior to V7.2.2
  • SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1): All versions prior to V7.2.2
  • SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1): All versions prior to V7.2.2
  • SCALANCE S615 (6GK5615-0AA00-2AA2): All versions prior to V7.2.2
  • SCALANCE S615 EEC (6GK5615-0AA01-2AA2): All versions prior to V7.2.2

3.2 Vulnerability Overview

3.2.1 ACCEPTANCE OF EXTRANEOUS UNTRUSTED DATA WITH TRUSTED DATA CWE-349

Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.

CVE-2023-44317 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS COMMAND (‘OS COMMAND INJECTION’) CWE-78

An improper neutralization of special elements used in an OS command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.

CVE-2023-49692 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-068047 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • December 14, 2023: Initial Publication

CISA and Partners Release Advisory on Russian SVR-affiliated Cyber Actors Exploiting CVE-2023-42793

Today, CISA—along with the U.S. Federal Bureau of Investigation (FBI), National Security Agency (NSA), Polish Military Counterintelligence Service (SKW), CERT Polska (CERT.PL), and the UK’s National Cyber Security Centre (NCSC)—released a joint Cybersecurity Advisory (CSA), Russian Foreign Intelligence Service (SVR) Exploiting JetBrains TeamCity CVE Globally.

Since September 2023, Russian Foreign Intelligence Service (SVR)-affiliated cyber actors (also known as Advanced Persistent Threat 29 (APT 29), the Dukes, CozyBear, and NOBELIUM/Midnight Blizzard) have been targeting servers hosting JetBrains TeamCity software that ultimately enabled them to bypass authorization and conduct arbitrary code execution on the compromised server. The joint CSA provides information on the SVR’s most recent compromise, actionable indicators of compromise (IOCs), and SIGMA and YARA rules.

The authoring agencies encourage network defenders and organizations review the joint CSA for recommended mitigations and rules. For more information on affiliated advanced persistent threats, see CISA’s Advanced Persistent Threats and Nation-State Actors and Russia Cyber Threat Overview and Advisories webpages. For more guidance to protect against the most common and impactful threats, visit CISA’s Cross-Sector Cybersecurity Performance Goals.