Siemens SICAM A8000 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely
  • Vendor: Siemens
  • Equipment: SICAM A8000
  • Vulnerability: Path Traversal

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to traverse directories, download arbitrary files, or escalate privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens SICAM A8000, a remote terminal unit, are affected:

  • CP-8031 MASTER MODULE (6MF2803-1AA00): All versions prior to CPCI85 V05.11
  • CP-8050 MASTER MODULE (6MF2805-0AA00): All versions prior to CPCI85 V05.11

3.2 Vulnerability Overview

3.2.1 Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) CWE-22

The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint. This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role.

CVE-2023-42796 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Meta reported this vulnerability to Siemens.

4. MITIGATIONS

Siemens has released updates for the affected products and recommends users update to the latest versions.:

Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:

  • Restrict network access to the integrated web server.
  • Review the list of users that are allowed to log in to the integrated web server and apply strong passwords.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-770890 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.

5. UPDATE HISTORY

  • October 12, 2023: Initial Publication

CISA Adds Five Known Vulnerabilities to Catalog

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation:

  • CVE-2023-21608 Adobe Acrobat and Reader Use-After-Free Vulnerability
  • CVE-2023-20109 Cisco IOS and IOS XE Group Encrypted Transport VPN Out-of-Bounds Write Vulnerability
  • CVE-2023-41763 Microsoft Skype for Business Privilege Escalation Vulnerability
  • CVE-2023-36563 Microsoft WordPad Information Disclosure Vulnerability
  • CVE-2023-44487 HTTP/2 Rapid Reset Attack Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Note: To view other newly added vulnerabilities in the catalog, click on the arrow in the “Date Added to Catalog” column—which will sort by descending dates.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Hitachi Energy AFS65x, AFF66x, AFS67x, and AFR67x Series Products

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Hitachi Energy
  • Equipment: AFS65x, AFF66x, AFS67x, AFR67x Series
  • Vulnerabilities: Incorrect Calculation, Integer Overflow or Wraparound, Improper Encoding or Escaping of Output, Exposure of Resource to Wrong Sphere

2. RISK EVALUATION

Successful exploitation of these vulnerabilities by an attacker could have a high impact on availability, integrity, and confidentiality of the targeted devices.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Hitachi Energy products and versions are affected:

  • AFF66X FW: 03.0.02 and prior
  • AFS66X-S: All versions
  • AFS660-C: All versions
  • AFS66X-B: All versions
  • AFS670-V20: All versions
  • AFS65X: All versions
  • AFS67X: All versions
  • AFR677: All versions

3.2 Vulnerability Overview

3.2.1 INCORRECT CALCULATION CWE-682

In Expat (aka libexpat) before 2.4.3, a left shift by 29(or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).

CVE-2021-45960 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.2 INTEGER OVERFLOW OR WRAPAROUND CWE-190

In doProlog in xmlparse.c in Expat (aka libexpat) before 2.4.3, an integer overflow exists for m_groupSize.

CVE-2021-46143 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.3 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Vulnerable code using addBinding in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

CVE-2022-22822 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.4 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Vulnerable code using build_model in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

CVE-2022-22823 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.5 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Vulnerable code using defineAttribute in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

CVE-2022-22824 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.6 INTEGER OVERFLOW OR WRAPAROUND CWE-190

The lookup in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

CVE-2022-22825 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.7 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Vulnerable code using nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow

CVE-2022-22826 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H ).

3.2.8 INTEGER OVERFLOW OR WRAPAROUND CWE-190

An insecure direct object reference for the file-download URL in Synametrics SynaMan before 5.0 allows a remote attacker to access unshared files via a modified base64-encoded filename string.

CVE-2022-22827 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.9 INTEGER OVERFLOW OR WRAPAROUND CWE-190

In Expat (aka libexpat) before 2.4.5, there is an integer overflow in copyString.

CVE-2022-25314 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.10 INTEGER OVERFLOW OR WRAPAROUND CWE-190

In Expat (aka libexpat) before 2.4.5, there is an integer overflow in storeRawNames

CVE-2022-25315 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.11 IMPROPER ENCODING OR ESCAPING OF OUTPUT CWE-116

Vulnerable code in xmltok_impl.c in Expat (aka libexpat) before 2.4.5 lacks certain validation of encoding, such as checks for whether a UTF-8 character is valid in a certain context.

CVE-2022-25235 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.12 EXPOSURE OF RESOURCE TO WRONG SPHERE CWE-668

Vulnerable code in xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.

CVE-2022-25236 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.13 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Expat (aka libexpat) before 2.4.4 has a signed integer overflow in XML_GetBuffer, for configurations with a nonzero XML_CONTEXT_BYTES

CVE-2022-23852 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.14 INTEGER OVERFLOW OR WRAPAROUND CWE-190

Expat (aka libexpat) before 2.4.4 has an integer overflow in the doProlog function.

CVE-2022-23990 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Hitachi Energy reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi energy recommends the following actions:

  • AFF66X FW 03.0.02 and earlier:
    • For all vulnerabilities, apply mitigation strategy as described in Hitachi Energy’s general mitigation factors below or update to upcoming AFF66X 04.x.xx FW when released.
  • AFS66X-S, AFS660-C, AFS66X-B, AFS670-V20 devices:
    • For all vulnerabilities, apply mitigation strategy as described in Hitachi Energy’s general mitigation factors below or update to upcoming AFS66X, AFS670-V20 7.1.08 FW when released.
    • Disable HTTP/HTTPS server or restrict access to HTTP/HTTPS to trusted IP addresses.
    • Disable IEC61850-MMS server or restrict access to IEC61850-MMS to trusted IP addresses.
  • AFS65X, AFS67X, AFR677 devices:
    • For all vulnerabilities, apply mitigation strategy as described in Hitachi Energy’s general mitigation factors below or update to AFS65X, AFS67X, AFR677 09.1.08 FW.
    • Disable HTTP/HTTPS server or restrict access to HTTP/HTTPS to trusted IP addresses.
    • Disable IEC61850-MMS server.

Hitachi Energy’s general mitigation factors:
Security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

For more information, please visit Hitachi Energy’s Advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 5, 2023: Initial Publication

Qognify NiceVision

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Qognify
  • Equipment: NiceVision
  • Vulnerability: Use of Hard-coded Credentials

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to retrieve sensitive information about the cameras managed by the platform and its users.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Qoginfy NiceVision, an IP-video surveillance system, are affected:

  • NiceVision: v3.1 and prior

3.2 Vulnerability Overview

3.2.1 USE OF HARD-CODED CREDENTIALS CWE-798

Qognify NiceVision versions 3.1 and prior are vulnerable to exposing sensitive information using hard-coded credentials. With these credentials an attacker can retrieve information about the cameras, user information, and modify database records.

CVE-2023-2306 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Roni Gavrilov of OTORIO reported this vulnerability to CISA.

4. MITIGATIONS

Qognify has released NiceVision v3.2 UP2 HF2. The latest release is available to customers who have an active SMA (Service Maintenance Agreement) with Qognify.

For more information contact Qognify.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 05, 2023: Initial Publication

Atlassian Releases Security Advisory for Confluence Data Center and Server

Atlassian released a security advisory to address a vulnerability affecting Confluence Data Center and Confluence Server. A remote cyber threat actor could exploit this vulnerability to take control of an affected system.

CISA encourages users and administrators to review the following advisory and apply the necessary updates: CVE-2023-22515 – Privilege Escalation Vulnerability in Confluence Data Center and Server.

CISA Releases Three Industrial Control Systems Advisories

CISA released three Industrial Control Systems (ICS) advisories on October 5, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.