Siemens SINEC Security Monitor

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.4
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINEC Security Monitor
  • Vulnerabilities: Argument Injection, Command Injection, Path Traversal, Permissive List of Allowed Inputs

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, execute privileged commands, or compromise the integrity of the configuration of the affected application.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens SINEC Security Monitor, a modular cyber security software, are affected:

  • SINEC Security Monitor: All versions prior to V4.9.0

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF ARGUMENT DELIMITERS IN A COMMAND(‘ARGUMENT INJECTION’) CWE-88

The affected application does not properly validate user input to the ssmctl-client command. This could allow an authenticated, lowly privileged remote attacker to execute arbitrary code with root privileges on the underlying OS.

CVE-2024-47553 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-47553. A base score of 9.4 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.2.2 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND (‘COMMAND INJECTION’) CWE-77

The affected application does not properly neutralize special elements in user input to the ssmctl-client command. This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.

CVE-2024-47562 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-47562. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.2.3 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY (‘PATH TRAVERSAL’) CWE-22

The affected application does not properly validate a file path that is supplied to an endpoint intended to create CSR files. This could allow an unauthenticated remote attacker to create files in writable directories outside the intended location and thus compromise integrity of files in those writable directories.

CVE-2024-47563 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2024-47563. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N).

3.2.4 PERMISSIVE LIST OF ALLOWED INPUTS CWE-183

The affected application does not properly validate that user input complies with a list of allowed values. This could allow an authenticated remote attacker to compromise the integrity of the configuration of the affected application.

CVE-2024-47565 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2024-47565. A base score of 5.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • SINEC Security Monitor: Update to V4.9.0 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-430425 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 10, 2024: Initial Publication

Siemens Teamcenter Visualization and JT2Go

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.3
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: Teamcenter Visualization and JT2Go
  • Vulnerabilities: Stack-based Buffer Overflow, NULL Pointer Dereference

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to crash the application or perform arbitrary code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens Teamcenter Visualization and JT2Go are affected:

  • JT2Go: All versions prior to V2406.0003
  • Teamcenter Visualization V14.2: All versions prior to V14.2.0.13
  • Teamcenter Visualization V14.3: All versions prior to V14.3.0.11
  • Teamcenter Visualization V2312: All versions prior to V2312.0008
  • Teamcenter Visualization V2406: All versions prior to V2406.0003

3.2 Vulnerability Overview

3.2.1 NULL POINTER DEREFERENCE CWE-476

The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.

CVE-2024-37996 has been assigned to this vulnerability. A CVSS v3.1 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).

A CVSS v4 score has also been calculated for CVE-2024-37996. A base score of 4.8 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.2.2 STACK-BASED BUFFER OVERFLOW CWE-121

The affected applications contain a stack-based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.

CVE-2024-37997 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-37997. A base score of 7.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • JT2Go: Update to V2406.0003 or later version
  • Teamcenter Visualization V14.2: Update to V14.2.0.13 or later version
  • Teamcenter Visualization V14.3: Update to V14.3.0.11 or later version
  • Teamcenter Visualization V2312: Update to V2312.0008 or later version
  • Teamcenter Visualization V2406: Update to V2406.0003 or later version

Siemens has identified the following specific workarounds and mitigations that users can apply to reduce the risk:

  • CVE-2024-37996, CVE-2024-37997: Do not open untrusted XML files in affected applications

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-959281 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.

5. UPDATE HISTORY

  • October 10, 2024: Initial Publication

CISA and FBI Release Fact Sheet on Protecting Against Iranian Targeting of Accounts Associated with National Political Organizations

Today, CISA and the Federal Bureau of Investigation (FBI) released joint fact sheet, How to Protect Against Iranian Targeting of Accounts Associated with National Political Organizations. This fact sheet provides information about threat actors affiliated with the Iranian Government’s Islamic Revolutionary Guard Corps (IRGC) targeting and compromising accounts of Americans to stoke discord and undermine confidence in U.S. democratic institutions.

IRGC actors have previously gained and continue to seek access to personal and business accounts using social engineering techniques by targeting victims across email and chat. This fact sheet includes steps that individuals and organizations can take to enhance their security and resilience to protect themselves against the common techniques used by these cyber actors.

CISA and FBI strongly recommend all individuals and organizations associated with national political organizations apply the mitigations in this fact sheet, including protecting their sensitive accounts with phishing-resistant multifactor authentication (MFA)

Election infrastructure stakeholders and the public can find more resources on how to protect against cyber and physical threats at #Protect2024. CISA encourages organizations to review its Iran Cyber Threat webpage for advisories and actions to defend their networks.

Subnet Solutions Inc. PowerSYSTEM Center

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: Subnet Solutions Inc.
  • Equipment: PowerSYSTEM Center
  • Vulnerabilities: Server-Side Request Forgery (SSRF), Inefficient Regular Expression Complexity, Cross-Site Request Forgery (CSRF)

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could result in an attacker bypassing a proxy, creating a denial-of-service condition, or viewing sensitive information.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of PowerSYSTEM Center are affected:

  • PowerSYSTEM Center: PSC 2020 v5.21.x and prior

3.2 Vulnerability Overview

3.2.1 SERVER-SIDE REQUEST FORGERY (SSRF) CWE-918

Vulnerable versions of PowerSYSTEM Center utilize Axios NPM package 0.21.0, which contains a Server-Side Request Forgery (SSRF) vulnerability where an attacker is able to bypass a proxy by providing a URL that responds with a redirect to a restricted host or IP address.

CVE-2020-28168 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.2.2 INEFFICIENT REGULAR EXPRESSION COMPLEXITY CWE-1333

Vulnerable versions of PowerSYSTEM Center utilize Axios, which is vulnerable to Inefficient Regular Expression Complexity.

CVE-2021-3749 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.3 CROSS-SITE REQUEST FORGERY (CSRF) CWE-352

Vulnerable versions of PowerSYSTEM Center utilize Axios 1.5.1, which can inadvertently reveal the confidential XSRF-TOKEN stored in cookies by including it in the HTTP header X-XSRF-TOKEN for every request made to any host, allowing attackers to view sensitive information.

CVE-2023-45857 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Canada

3.4 RESEARCHER

Subnet Solutions Inc. reported this vulnerability to CISA.

4. MITIGATIONS

Subnet Solutions Inc. recommends users update to PowerSYSTEM Center 2020 Update 22, which can be located in the PowerSYSTEM Center by accessing Settings > Overview > Version. Users may also contact Subnet Solution’s Customer Service.

Subnet Solutions Inc. strongly recommends users update to the latest version. If this is not possible, the following paragraphs describe the security control compensation(s), mitigation(s), or workaround(s) available for identified vulnerabilities:

  • For all vulnerabilities, users can disable usage of previous UI extensions.
  • For CVE-2020-28168 and CVE-2023-45857, users can limit outbound connection requests from the PowerSYSTEM Center security zone to external websites.
  • For CVE-2023-45857 and CVE-2021-3749, users can disable PowerSYSTEM Center Client Access Server user’s ability to access the browser’s F12 Developer Tools to limit user ability to see HTTP headers and corresponding XSRF-TOKEN, and to manipulate requests to the PowerSYSTEM Center website.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 3, 2024: Initial Publication

ASD’s ACSC, CISA, FBI, NSA, and International Partners Release Guidance on Principles of OT Cybersecurity for Critical Infrastructure Organizations

Today, the Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC)—in partnership with CISA, U.S. government and international partners—released the guide Principles of Operational Technology Cybersecurity. This guidance provides critical information on how to create and maintain a safe, secure operational technology (OT) environment.

The six principles outlined in this guide are intended to aid organizations in identifying how business decisions may adversely impact the cybersecurity of OT and the specific risks associated with those decisions. Filtering decisions that impact the security of OT will enhance the comprehensive decision-making that promotes security and business continuity.

CISA encourages critical infrastructure organizations review the best practices and implement recommended actions which can help ensure the proper cybersecurity controls are in place to reduce residual risk in OT decisions.

For more information on OT cybersecurity, review our Industrial Control Systems page and the Joint Cybersecurity Advisory Immediate Actions to Reduce Exposure Across Operational Technologies and Control Systems to help critical infrastructure organizations manage and enhance their OT cybersecurity.

Mitsubishi Electric MELSEC iQ-F FX5-OPC

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Mitsubishi Electric
  • Equipment: MELSEC iQ-F FX5-OPC
  • Vulnerability: NULL Pointer Dereference

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a remote attacker to cause a Denial-of-Service (DoS) condition on the product by getting a legitimate user to import a specially crafted PKCS#12 format certificate.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Mitsubishi Electric products are affected:

  • MELSEC iQ-F FX5-OPC: All versions

3.2 Vulnerability Overview

3.2.1 NULL POINTER DEREFERENCE CWE-476

A Denial-of-Service (DoS) vulnerability due to NULL Pointer Dereference when processing PKCS#12 format certificate exists in OpenSSL installed on MELSEC iQ-F OPC UA Unit. Because OpenSSL does not correctly check if a certain field in the PKCS#12 format certificate is NULL, a NULL pointer dereference occurs when the field is NULL, causing the product to enter a Denial-of-Service condition.

CVE-2024-0727 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Japan

3.4 RESEARCHER

Mitsubishi Electric reported this vulnerability to CISA.

4. MITIGATIONS

Mitsubishi Electric recommends users take the following mitigations to minimize the risk of exploiting this vulnerability:

  • Use within a LAN and block access from untrusted networks and hosts through firewalls.
  • Restrict physical access to the product, as well as to computers and network devices located within the same network as the product.
  • Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.
  • Use IP filter function to block access from untrusted hosts. For details on the IP filter function, please refer to the following manual. MELSEC iQ-F FX5 OPC UA Module User’s Manual “4.4 IP Filter”
  • Do not import untrusted certificates.

For additional details, see Mitsubishi Electric advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 1, 2024: Initial Publication